Fire Alarm Systems

Fire alarm systems are important to every business. This importance requires skill and expertise from design to installation. There are many different codes that must be adhered to. Improper installation and design leads to false alarms that will cost your business money. FSCI has over 25 years of experience in design and installation. Read the tips to the right on this page. Following those tips could save you thousands of dollars and unwanted fines. Trusting your fire alarm system to anyone that is not licensed puts you at great risk. FSCi employees only licensed and very experienced installers and designers.

FX-64R BY GE Security

Fire Alarm Control Panel, FX intelligent addressable, 64 points, 24VDC, red

The FireworX FX-64 life safety system offers the reliability of intelligent addressable fire detection for small to mid-sized applications. Built to provide years of trouble-free service, this system benefits building owners and installers with rotary device addressing, optional Ethernet® connectivity, and a full line of easily-to-configure option cards and modules.  

Standard Features

  • Comes standard with one loop that supports up to 64 intelligent addressable devices of any type and two Class B NACs
  • Form C contacts for alarm and trouble, Form A for supervisory
  • Rotary addressing
  • Optional Ethernet port for diagnostics, programming and a variety of system reports
  • Two programmable switches with LEDs and custom labeling
  • Supports horn silence over two wires and UL 1971-compliant strobe synchronization
  • Optional Class A wiring
  • Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface).
  • Can use existing wiring for most retrofit applications
  • Upload/download remotely or locally
  • Two-level maintenance alert reporting
  • Pre-alarm and alarm verification by point
  • Adjustable detector sensitivity
  • 4 x 20 character backlit LCD display

FX-254RD BY GE Security

Fire Alarm Control Panel, FX intelligent addressable, 127 std. up to 254 points., w/U/D dialer, red

The FireworX FX-254 life safety system offers the reliability of intelligent addressable fire detection for small to mid-sized applications. Built to provide years of trouble-free service, this system benefits building owners and installers with rotary device addressing, optional Ethernet® connectivity, and a full line of easily-to-configure option cards and modules.  

Standard Features


  • Comes standard with one loop (expandable to two) that supports up to 127 (expandable to 254) intelligent addressable devices
  • Supports intelligent modules, pull stations, detectors, and bases
  • Four Class B NACs or two Class A NACs.
  • Form C contacts for alarm and trouble, Form A for supervisory
  • Rotary addressing on all intelligent addressable devices
  • Optional Ethernet port for diagnostics, programming and a variety of system reports
  • Two programmable switches with LEDs and custom labeling
  • Supports horn silence over two wires and UL 1971-compliant strobe synchronization
  • Standard Class A wiring
  • Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface).
  • Can use existing wiring for most retrofit t applications
  • Upload/download remotely or locally
  • Two-level maintenance alert reporting
  • Pre-alarm and alarm verification by point
  • Adjustable detector sensitivity
  • 4 x 20 character backlit LCD display

 



 

SFC 500 Summit Fire Alarm Control Panel

 

The SFC-500

The SFC-500 Series Fire Alarm Control Panels are single loop addressable panels with support for up to 60 or 126 addressable points. The SFC-500 Series panels are equipped with a two line by 20 character back-lit LCD display, numerical keypad and an integrated UDACT/Digital Communicator. The SFC-500 Series family also includes remote LED and LCD annunciators. The SFC-500 Series panels are ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today’s installation demands. The SFC-500 Series panels are configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the SFC-500 Series panels enable the installer to configure the system to meet their specific requirements

.Silent Knight Fire Control Panel Conventional

 

SK-5208
Conventional Fire Alarm Control Panel

The fire alarm control designed to grow with your systems needs, without the growing pains.

The SK-5208 is a microprocessor based control panel with integrated UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation and auxiliary relay expansion. Ideal for new and retrofit applications.

Firelite 9200UDLS Fire Control

MS-9200UDLS Rev. 2 198-Point Intelligent Control

The new MS-9200UDLS Rev 2 adds new features such as USB Port, ANN-Bus devices and improved on-board communicator that provides support for the changing phone service environment. The MS-9200UDLS is ideal for commercial, industrial, manufacturing, office buildings, schools, strip malls and other facilities requiring performance-based, sophisticated technology at reasonable cost.

 

MS-9600LS 636-Point Intelligent Control

The Fire-Lite MS-9600LS and MS-9600UDLS are a compact, cost-effective, intelligent addressable fire alarm control panel with a capacity of 318 addressable Fire-Lite devices on one Signaling Line Circuit (SLC) or a total of 636 addressable points with an optional second loop (SLC-2LS).

 

 

 







What You Should know before you buy a fire alarm system:
  • Always buy a commonly sold system that has more than 1 local vendor. If you do not you may end up paying inflated maintenance cost during the systems life.
  • Make sure the installers carry an electrical license for Nebraska.
  • Make sure every system inspector shows you their Inspectors License.
  • Always demand a detailed contract so you know what you are suppose to get.
  • Always insist on as-built drawings when your installation is finished. These drawings are required by code and the state fire marshal.
  • Always make sure a permit has been taken out on your system before work starts. This could save you expensive changes. Ask to see the approval paperwork.
  • Make sure the central station that may monitor your alarm is UL Listed or FM listed. This insures that proper monitoring equipment and personnel are being used. There are too many fly by night central stations.
  • Never let an apprentice work by themselves on your project. A licensed person must provide direct oversight  at all times. There is a reason they are just an apprentice.