GE Security Fire Alarm Detectors and Modules
When choosing smoke detectors make sure they go with the system
manufacturer you have chosen. For example if you are buying a GE
Security Fireworx system then buy detectors that are listed under GE
Security Fireworx header.
GE Security Fireworx Addressable Smoke
Detectors
FX-PD
Smoke Detector Head, FireworX intelligent addressable, photo,
requires B4U Series base
|
This intelligent analog device uses an optical sensing
chamber to detect smoke. The detector analyzes data
gathered by the sensor to determine when an alarm is
initiated. The detector continuously adjusts its
sensitivity based on fluctuating environmental
conditions such as the presence of dirt, smoke,
humidity, or changes in temperature, and notifies the
loop controller of any changes in sensor sensitivity.
When the detector approaches its preset sensitivity
threshold, it issues a dirty sensor warning, allowing
enough of a margin for maintenance personnel to clean
the detector before it goes into trouble condition.
|
|
Standard Features
- Optical, heat, and multisensor models available
- Field replaceable optical chamber
- Highly stable design
- Compatible standard, relay, isolator, and audible bases
- Bases mount to standard North American two-gang or 4 square
- electrical boxes
- Twist-and-lock installation
- At-a-glance alarm indication
- Tamper-resistant feature
- Self diagnostic capability with on-board storage of results
- Optical detectors feature automatic rate compensated
sensitivity adjustment, as well as dirty sensor warnings
- Manufactured to strict international ISO 9001 standards
- Assembled using surface mount technology for RF resistance
- Conformally coated components resist dust and humidity
- Automatic detector test
- Low Profi le design
Click here to view the FX-PD Data Sheet
FX-HD
Heat Detector Head, FireworX intelligent
addressable, fixed, requires B4U Series base
|
This intelligent analog device provides
a 135°F (57°C) fixed-temperature heat
sensor for the detection of heat due to
fire. The heat sensor monitors the
temperature of the air and determines
whether an alarm should be initiated.
The FX-HD is capable of performing
comprehensive self-diagnostics and
storing the results.
|
|
|
Standard Features
- Optical, heat, and multisensor models
available
- Field replaceable optical chamber
- Highly stable design
- Compatible standard, relay, isolator, and
audible bases
- Bases mount to standard North American
two-gang or 4 square
- electrical boxes
- Twist-and-lock installation
- At-a-glance alarm indication
- Tamper-resistant feature
- Self diagnostic capability with on-board
storage of results
- Optical detectors feature automatic rate
compensated sensitivity adjustment, as well as
dirty sensor warnings
- Manufactured to strict international ISO
9001 standards
- Assembled using surface mount technology for
RF resistance
- Conformally coated components resist dust
and humidity
- Automatic detector test
- Low Profi le design
FX-PDD
Duct Smoke Detector, FireworX
intelligent addressable, photo,
rotary dials
|
The FX-PDD features a
unique design that
speeds installation and
simplifies maintenance.
Removable dust filters,
conformally coated
circuit boards, and
optional water-resistant
gaskets keep
contaminants away from
components, ensuring
years of trouble-free
service. When cleaning
is required, the
assemblies come apart
easily and snap back
together in seconds. The
duct smoke detector’s
primary purpose is to
provide early warning of
an impending fire and
shut down the HVAC unit
in order to prevent
smoke from circulating
throughout the building.
The duct smoke detector
is designed for use in
duct applications where
temperatures can exceed
standard detector
capabilities.
|
|
|
Standard Features
- Less than 2 deep for easy
installation and applications
where space is tight
- 32 to 120 °F (0 to 50 °C)
operating range with 100 ft/min.
to 4,000 ft/min air velocity
rating assures reliability under
harsh environmental conditions
- Status LEDs remain visible
through clear assembly cover
- Cover monitor switch for
added security
- Standard sampling tube
spacing for easy drop-in
migration from other detectors
- Sampling tube can be
installed with or without the
cover in place and can be
rotated in 45-degree increments
to ensure proper alignment with
duct airflow
- 15.2 to 19.95 Vdc operation
- Magnet-activated test switch
- One Form C auxiliary alarm
relay for controlling ancillary
equipment (e.g., HVAC controls)
- No special tools required
for easy access to field
connections
- Environmental compensation
with differential sensing for
reliable, stable, and drift-free
sensitivity
- Wide 0.79% to 2.46%
obscuration/ft. smoke
sensitivity
- Identification of dirty or
defective detectors
Click here to view installation PDF
file.
<
|